Mã lỗi 042-313 — Xerox WorkCentre 6605

Code: 042-313

Description: IOT Fan Motor Failure Detect Fan Motor Error
Causes: • Main Fan (PL4.1.13) • Top Harness Assembly (PL18.2.5) • LVPS (PL18.1.34) • MCU Board (PL18.1.13)
Remedy: 1 Check the Main Fan operation Execute Digital Output diagnostic test 042-001, and check the Main Fan rotation. Does the Main Fan function normally? Replace the MCU Board. Go to step 2. 2 Check the Main Fan installation Rotate the Main Fan manually. Is there an overload? Reinstall the Main Fan appropriately. Go to step 3. 3 Check the Main Fan connection Check the connection between the Main Fan and the LVPS. Is P/J503 connected securely? Go to step 4. Reconnect P/J503 securely. 4 Check the connections between the LVPS and the MCU Board Are P/J501 and P/J29 connected securely? Go to step 5. Reconnect P/J501 and P/J29 securely. 5 Check the continuity between the LVPS and the MCU Board Is each cable of P/J501<=>P/J29 continuous? Go to step 6. Replace the Top Harness Assembly. 6 Check after replacing the Main Fan Replace the Main Fan. Does the error still occur? Replace the LVPS. Finished.