Code: 046-310
Description: IOT HVPS Error Detect HVPS Error
Causes: • Transfer HVPS Board (PL18.1.28) • Development HVPS Board (PL18.1.14) • MCU-HVPS Flat Flex Cable (PL18.2.7) • HVPS Harness Assembly (PL18.2.6) • MCU Board (PL18.1.13)
Remedy: 1 Check the Transfer HVPS Board connection Check the connection between the Transfer HVPS Board and the Development HVPS Board. Are P/J1821 and P/J182 connected securely? Go to step 2. Connect P/J1821 and P/J182 securely. 2 Check the continuity between the Transfer HVPS Board and the Development HVPS Board Is each cable of P/J1821<=>P/J182 continuous? Go to step 3. Replace the HVPS Harness Assembly. 3 Check the Development HVPS Board connection Check the connection between the Development HVPS Board and the MCU Board. Are P/J181 and P/J18 connected securely? Go to step 4. Connect P/J181 and P/J18 securely. 4 Check after replacing the MCU-HVPS Flat Flex Cable Replace the MCU-HVPS Flat Flex Cable. Does the error still occur? Go to step 5. Finished. 5 Check after replacing the Transfer HVPS Board Replace the Transfer HVPS Board. Does the error still occur? Go to step 6. Finished. 6 Check after replacing the Development HVPS Board Replace the Development HVPS Board. Does the error still occur? Replace the MCU Board. Finished.