Code: 092-661
Description: IOT Environment Sensor Error Detect Environment Sensor Error
Causes: • Laser Unit (PL2.1.1) • Top Harness Assembly (PL18.2.5) • LVPS (PL18.1.34) • MCU Board (PL18.1.13)
Remedy: 1 Check the Laser Unit connection Check the connection between the Laser Unit and the MCU Board, and the connection between the Laser Unit and the PWBA LVPS. Are P/J36, P/J11, and PJ43 connected securely? Go to step 2. Connect P/J36, P/J11, and PJ43 securely. 2 Check the continuity between the LVPS and the Laser Unit Is each cable of P/J43<=>P/J431 continuous? Go to step 3. Replace the Top Harness Assembly. 3 Check the power to the Laser Unit (+5 VDC) Close the interlock switch(es), and check if the voltage between the LVPS ground and the P/J43-2 pin is about +5 VDC. Go to step 4. Replace the LVPS. 4 Check the power to the Laser Unit (+24 VDC) Close the interlock switch(es), and check if the voltage between the MCU Board ground and the P/J36-1 pin is about +24 VDC. Go to step 5. Refer to “+24 VDC Power FIP”. 5 Check the power to the Laser Unit (+3.3 VDC) Check if the voltage between the MCU Board ground and the P/J11-1 pin is about +3.3 VDC. Go to step 6. Refer to “+3.3 VDC Power FIP”. 6 Check after replacing the Laser Unit Replace the Laser Unit. Does the error still occur? Replace the MCU Board. Finished.