Mã lỗi 093-320 — Xerox WorkCentre 6605

Code: 093-320

Description: IOT Deve Motor Fail Detect Developer Motor Failure
Causes: • Developer Motor [Drive Assembly] (PL3.1.1) • Drive Harness Assembly (PL18.2.2) • Top Harness Assembly (PL18.2.5) • LVPS (PL18.1.34) • MCU Board (PL18.1.13)
Remedy: 1 Check the Developer Motor operation Execute Digital Output diagnostic test 093-001, and check the Developer Motor rotation. Does the Developer Motor function normally? Replace the MCU Board. Go to step 2. 2 Check the Developer Motor connection Check the connection between the Developer Motor and the MCU Board. Are P/J331 and P/J33 connected securely? Go to step 3. Connect P/J331 and P/J33 securely. 3 Check the continuity between the Developer Motor and the MCU Board Is each cable of P/J331<=>P/J33 continuous? Go to step 4. Replace the Drive Harness Assembly. 4 Check the power to the Developer Motor (+24 VDC) Close the interlock switch(es), and check if the voltage between the MCU Board ground and the P/J33-2 pin, and the voltage between the MCU Board ground and the P/J33-4 pin is about +24 VDC. Replace the Drive Assembly. Replace the LVPS.