Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 173 — OKI B4600

Code: 173

Description: Upper Heater Temp, State: Low
Remedy: Turn the power off, then back on again. • Yes Is the thermistor open or shorted? Measure the resistance between thermistor contacts (heater contacts 120V/2Ω or 240V/7Ω, and thermistor contacts 200KΩ at room temperature) . • Yes Replace the fusing unit. • No Do the thermistor connector is connected to the high voltage/sensor board connector? • No Connect the thermistor connector property. • Yes Is the heater of the fusing unit turned on (when the heater is turned on, light is emitted)? • Yes Check the thermistor connector or replace the main control board or the fusing unit. • No Is the AC voltage being supplied to the connector for the heater of the power supply board? • No Replace the main control board or the power supply board. • Yes Check the heater connector cord and the heater connector for poor contact .

← Xem tất cả mã lỗi OKI B4600

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie