Mã lỗi 2-1 — OKI B730

Code: 2-1

Description: NVM Abnormality - Failure of the NVRAM occurred at powering on. - Write error to the NVRAM occurred.
Remedy: FIP1.1 Possible causative parts: HVPS/MCU 1 Does Error occur when the power is turned ON? Go to step 4. Go to step 2. 2 Does Error still occur when the power is turned OFF and ON again? Go to step 4. Go to step 3. 3 Does Error still occur after several ON/OFF procedures of the power? Go to step 4. End of work *1 4 Checking HVPS/MCU non-volatile memory setup mode Is non-volatile memory setup mode accessible? Checks by Chapter 2 Diagnostic [ADJUSTMENT PARAMETER INTIALIZE MODE]. Go to step 5. Replace HVPS/MCU. 5 Checking NVRAN for data setup Are all NVRAM data set appropriately? Checks by Chapter 2 Diagnostic [ADJUSTMENT PARAMETER INTIALIZE MODE]. Go to step 7. Go to step 6. 6 Checking Error after changing HVPS/MCU data setup Change NV RAM data to the correct setup value, and then turn the power ON again. Does Error still occur? Replace HVPS/MCU, then go to step 7. End of work 7 Checking after replacing HVPS/MCU Does Error occur? Go to FIP2.19 Electrical Noise. End of work