Code: 166
Display: Service call 166: Error
Description: An abnormality was detected with the power supply temperature thermistor.
01: Short 02: Open 03: High temp. 04: Low temp.
01: Short 02: Open 03: High temp. 04: Low temp.
Remedy: 01, 02: Does this error recur? Does this error recur? Does this error recur? Restore the power. Replace the low voltage power supply unit. Replace the CU/ PU board. Replace the cable between the low voltage power supply unit and the CU/PU board.
03: Does this error recur? Remove anything obstructing the ventilation slots if any and restore the power. Replace the low voltage power supply unit. Replace the CU/ PU board. Replace the cable between the low voltage power supply unit and the CU/PU board.
04: Does this error recur? Raise the room temperature and restore the power. Replace the low voltage power supply unit. Replace the CU/ PU board. Replace the cable between the low voltage power supply unit and the CU/PU board.
03: Does this error recur? Remove anything obstructing the ventilation slots if any and restore the power. Replace the low voltage power supply unit. Replace the CU/ PU board. Replace the cable between the low voltage power supply unit and the CU/PU board.
04: Does this error recur? Raise the room temperature and restore the power. Replace the low voltage power supply unit. Replace the CU/ PU board. Replace the cable between the low voltage power supply unit and the CU/PU board.