Mã lỗi 128 — OKI C942

Code: 128

Display: Service Call 128:Error
Description: 01: Fuser Exhaust Fan 1 02: Low Voltage Fan 03: PU Fan 05: Station 1 ID Intake Fan 09: Second Transfer Adsorption Fan 0A: Fuser Intake Fan 0B: Station 2 ID Intake Fan 0C: Duplex Fan 0D: Fuser Exhaust Fun 2 0E: Station 3 ID Intake Fan 0F: Station 4 ID Intake Fan 10: Station 5 ID Intake Fan
Remedy: Is the cable to respective fans connected properly? No Re-connect the fan properly. Yes Replace the fan motor. Does this error recur? No Replace the applicable PCB. 01: Driver relay PCB 02: Printer control PCB 03: Printer control PCB 05: Driver relay PCB 09: Rail unit relay PCB 0A: Driver relay PCB 0B: Driver relay PCB 0C: Duplex unit PCB 0D: Driver relay PCB 0E: Driver relay PCB 0F: Driver relay PCB 10: Driver relay PCB