Mã lỗi C1A0 — OKI CX1145

Code: C1A0

Description: LCF end fence motor abnormality
Remedy: Is the LCF end fence motor working? (Perform the output check: 03-207) ↓→ NO → 1) Check if the connector of the LCF end fence motor is disconnected. 2) Check if any of the connectors CN100, CN101 and CN103 on the LCF board is disconnected. 3) Check if the connector CN344 on the LGC board is disconnected. 4) Check if the connector pins are disconnected or the harnesses are open circuited. 5) Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 6) Replace the LCF end fence motor. 7) Replace the LCF board. 8) Replace the LGC board. YES Are the LCF end fence home/stop position sensors working? (Perform the input check: 03-[FAX]OFF/[5]/[A], /[5]/[B]) ↓→ NO → 1) Check if the connectors of the sensors are disconnected. 2) Check if either of the connectors CN100 or CN107 on the LCF board is disconnected. 3) Check if the connector CN344 on the LGC board is disconnected. 4) Check if the slit reaches the sensors. 5) Check if the connector pins are disconnected or the harnesses are open circuited. 6) Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 7) Replace the sensors. 8) Replace the LCF board. 9) Replace the LGC board. YES 1) Check if the conductor pattern on the LGC board is short circuited or open circuited. 2) Replace the LGC board.

← Xem tất cả mã lỗi OKI CX1145

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie