Code: CEF0
Description: Revolver motor abnormality
Remedy: Is the revolver motor working? (Perform the output check: 03-450) ↓→ NO → 1) Check if the connector of the revolver motor is disconnected. 2) Check if the connectors CN435 and CN434 on the DRV board are disconnected. 3) Check if the connector CN331 on the LGC board is disconnected. 4) Check if the connector pins are disconnected or the harnesses are open circuited. 5) Check if the conductor patterns on the DRV board and LGC board are short circuited or open circuited. 6) Replace the revolver motor. 7) Replace the DRV board and LGC board. YES 1) Check if the teeth of the revolver motor gear or the revolver unit gear do not get chipped or cracked. 2) Check if the conductor patterns on the DRV board and LGC board are short circuited or open circuited. 3) Replace the DRV board and LGC board.