Code: C020
Description: Developer motor abnormality
Remedy: Is the developer unit motor working? (Perform the output check: 03-112/162) ↓→ NO → 1) Check if the connector J578 of the developer motor is disconnected. 2) Check if the connector CN337 on the LGC board is disconnected. 3) Check if the connector pins are disconnected or the harnesses are open circuited. 4) Check if the conductor patterns on the developer motor board and LGC board are short circuited or open circuited. 5) Replace the developer motor. 6) Replace the LGC board. YES 1) Check if the PLL lock signal CN337-B6 pin output from the LGC board is always level “L”. 2) Check if the voltage supplied to the ASIC input terminal IC40-150 pin is always “L”. 3) Replace the LGC board.