Code: C280
Description: Carriage home position sensor not going ON within a specified time
Remedy: Remove the original glass and move the carriages to the paper feeding side. Turn ON the power and check the following items.
Do the carriages make a big noise after they arrive at the home position? ↓→ YES → The carriage home position sensor is not turned ON. 1) Check if the connector of the sensor is disconnected. 2) Check if the circuits of the SLG board are abnormal. NO The carriages are stopped at the home position and do not move. 1) Check if the connector pins are disconnected or the harnesses are short circuited or open circuited. 2) Check if the conductor pattern on the SLG board is short circuited or open circuited. 3) Replace the SLG board.
Do the carriages make a big noise after they arrive at the home position? ↓→ YES → The carriage home position sensor is not turned ON. 1) Check if the connector of the sensor is disconnected. 2) Check if the circuits of the SLG board are abnormal. NO The carriages are stopped at the home position and do not move. 1) Check if the connector pins are disconnected or the harnesses are short circuited or open circuited. 2) Check if the conductor pattern on the SLG board is short circuited or open circuited. 3) Replace the SLG board.