Code: C490
Description: IH control circuit or IH coil abnormality
Remedy: 1. Check the IH board (1) Check if the conductor pattern on the board is short circuited or open circuited. (2) Replace the IH board. 2. Check the IH coil (1) Check if the coil is broken or short out. (2) Replace the IH coil. 3. Clear the status counter Change the values “13”, “16” or “19” of the status counter (08-400) to “0”. * The status counter value is as follows in the following cases. Change them to "0" respectively. • The error occurred before the temperature of the fuser roller reaches 40°C: "13" • The error occurred before the equipment has become ready: "16" • The error occurred when the equipment is in the ready state: "19"
When the problem is solved, [C470], [C480] and [C490] can be cleared by turning OFF and ON the main switch so the status counter does not have to be changed to "0". The value of the status counter remains the same until the next service call overwrites the value.
When the problem is solved, [C470], [C480] and [C490] can be cleared by turning OFF and ON the main switch so the status counter does not have to be changed to "0". The value of the status counter remains the same until the next service call overwrites the value.