Code: CEB0
Description: Black developer unit lifting movement abnormality
Remedy: Black developer unit lifting movement abnormality Check the timing of the black developer lifting clutch (stop position), and adjust it if it deviates. → Is the black developer lifting clutch working properly? (Perform the output check: 03-433) ↓→ NO → 1) Check if the connector of the black developer lifting clutch is disconnected. 2) Check if the connector CN339 on the LGC board is disconnected. 3) Check if the connector pins are disconnected or the wires of harnesses are open circuited. 4) Check if the conductor pattern on the LGC board is short circuited or open circuited. 5) Replace the black developer lifting clutch. 6) Replace the LGC board. YES Are the black developer contact position detion sensor and black developer contact timing detion sensor working properly? (Perform the input check: 03-[FAX]ON/[1]/[C], /[1]/[B] ↓→ NO → 1) Check if the connectors of the black developer contact position detion sensor or black developer contact timing detion sensor are disconnected. 2) Check if the connector CN333 on the LGC board is disconnected. 3) Check if the connector pins are disconnected or the wires of harnesses are open circuited. 4) Check if the conductor pattern on the LGC board is short circuited or open circuited. 5) Replace the black developer contact position detion sensor and black developer contact timing detion sensor. 6) Replace the LGC board. YES 1) Check if the conductor pattern on the LGC board is short circuited or open circuited. 2) Replace the LGC board.