Code: C180
Description: LCF tray-up motor abnormality
Causes: LCF tray-up motor LCF board LGC board LCF tray-up sensor LCF tray bottom sensor
Remedy: 1 Does the tray move? (Perform the output check: 03-271) Yes 2 No • Check if the connector of the LCF tray-up motor is disconnected. • Check if any of the connectors CN100, CN101 and CN103 on the LCF board is disconnected. • Check if the connector CN349 on the LGC board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 2 Are the LCF tray-up sensor and LCF tray bottom sensor working? (Perform the input check: 03-[ALL]OFF/[0]/[F], /[9]/ [A]) Yes 3 No • Check if the connectors of the sensors are disconnected. • Check if any of the connectors CN100, CN104 and CN105 on the LCF board is disconnected. • Check if the connector CN349 on the LGC board is disconnected. • Check if the slit reaches the sensors. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the LCF board and LGC board are short circuited or open circuited. 3 LGC board • Check if the conductor pattern on the LGC board is short circuited or open circuited.