Description: Carriage home position sensor not going ON within a specified time
Causes: Home position sensor SLG board
Remedy: dure Check item Result Measure Next Step 1 Do the carriages make a big noise after they arrive at the home position? Yes 2 No 3 2 Home position sensor SLG board The carriage home position sensor is not turned ON. • Check if the connector of the sensor is disconnected. • Check if the circuits of the SLG board are abnormal. 3 SLG board The carriages are stopped at the home position and do not move. • Check if the connector pins are disconnected or the harnesses are short circuited or open circuited. • Check if the conductor pattern on the SLG board is short circuited or open circuited.