Code: CE40

Description: Image quality control test pattern abnormality. Image quality control test pattern abnormality: The test pattern is not formed normally
Causes:
Remedy: 1 <Color toner low density> Check the printing status. Is the color printing ratio 5% or more? Yes 2 No The color toner low density might be the cause. Turn the code 08-2692 "Prevention of color toner low density / ON/OFF setting" to ON, and then set number of sheets to be judged at the code 08- 2693 "Prevention of color toner low density/Judged number of sheets setting". 2 Check if there is any abnormality on the hand grips and rods of the main charger cleaner. Correct if there is. 3 Check if the drum is rotated properly by turning the coupling of the developer unit. Correct the auger and the surrounding hardware if not. 4 Laser optical unit • Check the connectors and harnesses between the LGC board (CN343, CN355, and CN356) and the laser optical unit. • Check if there is any stain or scratch on the glass surface of the laser optical unit. Clean or correct if there is. 5 Check if there is any stain on the image quality sensor and Image position aligning sensors. 6 Check if the sensor shutter is working properly. 7 Use “Image quality control abnormal detection counter Y to K display/0 clearing (08-2528 to 2531)” to check the abnormal occurring condition for each color. 8 Check “Output value display of image quality sensor / Low-density pattern (05-2732-0 to 3)” to check if the low-density pattern abnormality occurs for each color. Are the values 180 or more for Y, M and C, and 20 or more for K? Yes 10 No 9 9 Low-density pattern abnormality Check the transfer belt. If the cleaning is poor, check the installation status of the transfer belt cleaner unit and correct it if necessary. 19* 10 Check “Output value display of image quality sensor / Highdensity pattern (05-2731-0 to 3)” to check if the high-density pattern abnormality occurs for each color and identify the color which pattern is abnormal. Is the value 628 or less? Yes 13 No 11 11 High-density pattern abnormality Check if the laser shutter is working properly. 1. Take off the developer unit so that the laser shutter can be easily seen. Clean around the laser shutter if the developer has been spilled over. 2. While pressing the digital keys [0] and [3] simultaneously, turn the power ON. 3. Key in “417”. 4. Press the [START] button repeatedly to open and close the shutter alternatively. If the laser shutter does not open/ close, check the shutter and correct it if necessary. 12 Check if the developer unit has been installed properly. Visually check the installation status of the developer unit, and correct it if there is any abnormality. 19* 13 Set the values of "Image quality closed-loop control / Contrast voltage (08-2486)" and "Image quality closed-loop control / Laser power (08-2487)" to "0" (Invalid). 14 Perform "Enforced performing of image quality open-loop control (05-2740)". 15 Output the image quality control test pattern (04-270) more than one time and the list print ([9][START]), and check the patch of the color identified in step (7). Is the image normal? Yes 17 No 16 16 Abnormal image Correct the abnormal image. Blank print, Solid print, White banding, Color banding, White spots, Poor transfer, Uneven image density, Faded image (low density), Uneven light distribution, Blotched image. * Blank print: including when one of the YMCK colors is not printed. 18 17 Replace the image quality sensor or LGC board. 18 Set the values of “Image quality closed-loop control / Contrast voltage (08-2486)” and “Image quality closed-loop control / Laser power (08-2487)” to “1” (Valid). 19 Perform “Forced performing of image quality closed-loop control (05-2742).” Is it completed normally? Yes 21 No 20 20 Check and correct it accordingly. 21 Perform "Automatic gamma adjustment". 22 Clear all “Image quality control abnormal detection counter Y to K display/0 clearing (08-2528 to 2531)”. 23 Check if any of the springs for supplying power to the transfer belt unit is deformed. Replace the spring if it is deformed.

← Xem tất cả mã lỗi OKI CX3535 MFP

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie