Code: C150, C160
Description: [C150] PFP upper drawer tray abnormality [C160] PFP lower drawer tray abnormality
Causes: Tray-up motor PFP board LGC board Tray-up sensor
Remedy: dure Check item Result Measure Next Step 1 Does the tray go up? (Perform the output check: 03-278, 280) Yes 2 No • Check if the connector of the tray-up motor is disconnected. • Check if any of the connectors CN241, CN242 and CN244 on the PFP board is disconnected. • Check if the connector CN349 on the LGC board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the PFP board and LGC board are short circuited or open circuited. 2 Is the tray-up sensor working? (Perform the input check: 03-[ALL]OFF/ [4]/[B], /[4]/[A]) Yes 3 No • Check if the connector of the sensor is disconnected. • Check if any of the connectors CN241, CN247 and CN248 on the PFP board is disconnected. • Check if the connector CN349 on the LGC board is disconnected. • Check if the slit reaches the sensor. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the PFP board and LGC board are short circuited or open circuited. 3 LGC board • Check if the conductor pattern on the LGC board is short circuited or open circuited.