Code: C040
Description: PFP motor abnormality
Causes: PFP motor PFP board LGC board
Remedy: 1 Is the PFP motor working? (Perform the output check: 03-109/159) Yes 2 No • Check if the signal line connector CN503 of the PFP motor is disconnected. • Check if the power line connector CN502 of the PFP motor is disconnected. • Check if the connector CN246 on the PFP board is disconnected. • Check if the signal line connector CN241 on the PFP board is • Check if the power line connector CN242 on the PFP board is disconnected. • Check if the connector CN349 on the LGC board is disconnected. • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the PFP motor board, PFP board and LGC board are short circuited or open circuited. 2 Is the LED on the PFP motor board lit without flashing? Yes 3 No • Check if the connector pins are disconnected or the harnesses are open circuited. • Check if the conductor patterns on the PFP motor board, PFP board and LGC board are short circuited or open circuited. 3 PFP board • Check if the PLL lock signal CN246-8 pin output from the PFP board is always “L” level. • Check if the voltage supplied to the microcomputer input terminal IC5-17 pin is always “L” level.