Code: C4B1
Description: Fuser unit destination selection abnormality
Causes: LGC board
Remedy: The first occurrence of the error C4B1 is not the determination of the error. When the error C4B1 occurred, turn the power of the equipment OFF and then back ON following the instruction shown in the touch panel. If the abnormality is resolved, the value of the fuser unit status counter is automatically reset to “0“. When the error C4B1 occurred twice or more consecutively, the error is determined and recorded in the error history.
Fuser unit • Check if the fuser unit is installed correctly or if its destination is correct. • Check if any harness in the fuser unit is caught. LGC board • Check if the destination of the SRAM is correct.
Fuser unit • Check if the fuser unit is installed correctly or if its destination is correct. • Check if any harness in the fuser unit is caught. LGC board • Check if the destination of the SRAM is correct.