Code: CC30
Description: Stack delivery motor abnormality. Stack delivery motor abnormality: The stack delivery motor is not rotating normally.
Causes: Stack edging HP sensor (SR8) Stack slide motor (M4) Finisher controller PC board
Stack transport motor (M5) Finisher controller PC board
Stack transport motor Finisher control PC board
Stack transport motor (M5) Finisher controller PC board
Stack transport motor Finisher control PC board
Remedy: Stack edging HP sensor (SR8) Check the connectors and harnesses between the stack edging HP sensor (SR8) and the connector J111 on the finisher controller PC board. Stack slide motor (M4) Check the connectors and harnesses between the stack slide motor (M4) and the connector J106 on the finisher controller PC board.
MJ-1101 Stack transport belt If there is mechanical problem when the stack transport belt is moved, fix the mechanism. Stack transport motor (M5) Check the connectors and harnesses between the stack transport motor (M5) and the finisher control PC board (CN10).
MJ-1106 Stack transport belt Move the stack transport belt. Fix any mechanical problem. Stack transport motor Check if the connector (CN17) on the finisher controller PC board is disconnected from the stack transport motor (M8) and the harnesses are open circuited. Correct if so.
MJ-1101 Stack transport belt If there is mechanical problem when the stack transport belt is moved, fix the mechanism. Stack transport motor (M5) Check the connectors and harnesses between the stack transport motor (M5) and the finisher control PC board (CN10).
MJ-1106 Stack transport belt Move the stack transport belt. Fix any mechanical problem. Stack transport motor Check if the connector (CN17) on the finisher controller PC board is disconnected from the stack transport motor (M8) and the harnesses are open circuited. Correct if so.