Mã lỗi CC90 — OKI ES9460 MFP

Code: CC90

Description: Tray shift motor abnormality. Tray shift motor abnormality: The tray shift motor is not rotating or the stack tray is not moving normally.
Causes: Tray clock sensor (SR9) Tray lower limit sensor (SR5) Tray 500 sensor (SR4) Sensor controller PC board Finisher control PC board Tray shift motor (M2)
Remedy: MJ-1031 Tray shift motor (M2) Check the connectors and harnesses between the finisher controller PC board and tray shift motor (M2). Stack tray Check if the front and rear sides of the stack tray are leveled. Tray clock sensor (SR9) Sensor check Tray lower limit sensor (SR5) Sensor check Tray 500 sensor (SR4) Sensor check Tray safety switch (SW2) Switch check Finisher controller PC board Check if the voltage between the pins J114-1 and J114-2 on the finisher controller PC board becomes 24V when the tray shift motor starts rotating.