Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 108 — OKI ES9541dn

Code: 108

Display: Service Call 108:Error
Description: 01: Detection of a watchdog timer error 02: Detection of an undefined interruption 03: Runaway of the CPU on the PU due to noise etc. 04: Runaway of the Port CPU due to noise etc. 05: Failure of access to the Dcon circuit of the printer control PCB 09: Detection of an error in clock adjustment to the duplex unit 0B: Detection of an error in clock adjustment to Tray 2 0C: Detection of an error in clock adjustment to Tray 3 0D: Detection of an error in clock adjustment to Tray 4 0E: Detection of an error in clock adjustment to Tray 5 0F: Communication failure with the spot color PCB 10: Runaway of the Driver CPU due to noise etc.
Remedy: 01: Detection of a watchdog timer error Does this error recur? Yes Power OFF/ON. Replace the printer control PCB.
02: Detection of an undefined interruption Does this error recur? Yes Power OFF/ON. Replace the printer control PCB.
03: Runaway of the CPU on the PU due to noise etc. Does this error recur? Yes Power OFF/ON. Replace the printer control PCB.
04: Runaway of the Port CPU due to noise etc. Does this error recur? Yes Power OFF/ON. Replace the printer control PCB.
05: Failure of access to the Dcon circuit of the printer control PCB Does this error recur? Yes Power OFF/ON. Replace the printer control PCB.
09: Detection of an error in clock adjustment to the duplex unit Does this error message reappear after power restoration? Yes Replace the unit concerned. Does this error message reappear after power restoration? Yes Replace the printer control PCB.
0B: Detection of an error in clock adjustment to Tray 2 Does this error message reappear after power restoration? Yes Replace the unit concerned. Does this error message reappear after power restoration? Yes Replace the printer control PCB.
0C: Detection of an error in clock adjustment to Tray 3 Does this error message reappear after power restoration? Yes Replace the unit concerned. Does this error message reappear after power restoration? Yes Replace the printer control PCB.
0D: Detection of an error in clock adjustment to Tray 4 Does this error message reappear after power restoration? Yes Replace the unit concerned. Does this error message reappear after power restoration? Yes Replace the printer control PCB.
0E: Detection of an error in clock adjustment to Tray 5 Does this error message reappear after power restoration? Yes Replace the unit concerned. Does this error message reappear after power restoration? Yes Replace the printer control PCB.
0F: Communication failure with the spot color PCB Power OFF/ON. Does this error recur? Yes Replace the spot color PCB. Does this error recur? Yes Replace the printer control PCB.
10: Runaway of the Driver CPU due to noise etc. Does this error recur? Yes Power OFF/ON. Replace the driver relay PCB. Does this error recur? Yes Replace the printer control PCB.