Code: 121
Display: Service Call 121:Error
Description: High voltage power supply interface error
Remedy: Is the fuse on the printer control PCB blown? Yes Replace the printer control PCB (then check the following).
Is the cable connecting the printer control PCB to the high voltage power supply unit connected properly? No Re-connect it properly. Yes Check for defective contact points of the high voltage system.
Is there any defective contact point? No Replace the high voltage power supply unit.
Is the cable connecting the printer control PCB to the high voltage power supply unit connected properly? No Re-connect it properly. Yes Check for defective contact points of the high voltage system.
Is there any defective contact point? No Replace the high voltage power supply unit.