Code: 981
Display: Service call 981: Error
Description: Difference between PU model version detected and CU model version detected
High-voltage power supply I/F error when initializing
PU board SRAM error
CRC check error of PU download data
PU board Flash ROM hash check error
PU board Flash ROM writing error
The communication error with ASIC on the CU board is detected
High-voltage power supply I/F error when initializing
PU board SRAM error
CRC check error of PU download data
PU board Flash ROM hash check error
PU board Flash ROM writing error
The communication error with ASIC on the CU board is detected
Remedy: Does the error recur? Yes Turn off/on the power supply. Replace the M32 board.
Is the cable between PU board and the high-voltage power supply unit correctly connected? Isn’t there defective contact point?
Reconnect correctly.Check the defective contact point of highvoltage system. Replace the high voltage power supply.
Does the error recur? Yes Turn off the power supply again Replace the M32 board
After PU data is downloaded (PU fireware, custom media data, head correction data), CRC check error is detected. After the power supply is turned on again, try to download again. (Because this processing is not performed during usual operation, it does not occur.)
Does the error recur? Yes Turn on the power supply again Replace the M32 board
Does the error recur? fter the power supply is turned on again, try to download again. (Because this processing is not performed during usual operation, it does not occur.)
The communication error with ASIC on the CU board is detected. Replace the M32 board.
Is the cable between PU board and the high-voltage power supply unit correctly connected? Isn’t there defective contact point?
Reconnect correctly.Check the defective contact point of highvoltage system. Replace the high voltage power supply.
Does the error recur? Yes Turn off the power supply again Replace the M32 board
After PU data is downloaded (PU fireware, custom media data, head correction data), CRC check error is detected. After the power supply is turned on again, try to download again. (Because this processing is not performed during usual operation, it does not occur.)
Does the error recur? Yes Turn on the power supply again Replace the M32 board
Does the error recur? fter the power supply is turned on again, try to download again. (Because this processing is not performed during usual operation, it does not occur.)
The communication error with ASIC on the CU board is detected. Replace the M32 board.