Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi 142 — OKI MC573

Code: 142

Description: ID unit Up/Down error (Service call 142)
Remedy: Error occurs during the Up movement of the ID unit
(10-1-1) Check the mechanical load during the Up movement Mechanical load during installation and removal of the ID unit Check if abnormal heavy load is applied when removing the ID unit. Replace the ID unit, or replace the right/left side plate. Greasing to the right and left Up/Down link levers Check if the slant surface of the link lever is coated by grease or not. Apply grease. Assembled condition of the right and left Up/Down link levers Check if any part exists or not in the vicinity of link lever, that hampers movement of the link lever. Assemble them correctly. (10-1-2) Up/Down mechanism Assembled condition of the peripheral mechanism of the link lever Is the mechanism assembled so that the link lever is connected to the driving gear? Assemble them correctly. Right and left link levers Check if the link lever is set in the correct position that enables the specified engagement of gears. (Check if the link lever is set in the wrong position that results in the wrong engagement of gears by several teeth.) Assemble them correctly. (10-1-3) Sensor check Up/Down sensor lever (unified structure with the left link lever) Check if shape and movement of the sensor levers have any abnormality or not. Replace the left link lever. Up/Down sensor Confirm that the sensor signals are normally detected by using the SWITCH SCAN function of the self-diagnostic mode. Check if the SCAN state changes or not when the incoming light is interrupted/ passed by using a piece of paper or the like for the transparent type sensor. Replace the high voltage board.
Error occurs during the Down movement of the ID unit
(10-2-1) Check the mechanical load during the Down movement Mechanical load during installation and removal of the ID unit Check if abnormal heavy load is applied when removing the ID unit. Replace the ID unit, or replace the right/left side plate. Greasing to the right and left Up/Down link levers Check if the slant surface of the link lever is coated by grease or not. Apply grease. Assembled condition of the right and left Up/Down link levers Check if any part exists or not in the vicinity of link lever, that hampers movement of the link lever. Assemble them correctly.

← Xem tất cả mã lỗi OKI MC573

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie