Code: 153, 154, 155
Description: Fuse cut error (error codes 153 to 155)
Remedy: Connecting the CU/ PU board and the toner sensor board Check if the 20-conductor FFC is connected to SSNS connector of the CU/PU board and the CN1 connector of the 76E board is connected normally. Check if the connector is connected in the half-way only or not, and check if the connector is inserted in a slanted angle or not. Connect the FFC normally. Check if any peeling-off of sheath has occurred or not throughout the cable. Alternately, replace the FFC. (17-1-2) Fuse cut circuit CU/PU board Upon completion of the system connection check, turn off the power once and back on. The, check if the error occurs or not. Replace the CU/PU board.