Mã lỗi 170 ... 177 — OKI MC573dn

Code: 170 ... 177

Description: Fuser unit error (error 170 to 177)
Remedy: Error occurs immediately after the power is turned on.
(11-1-1) Thermistor is defective Note) Upper thermistor, lower thermistor, frame thermistor Check the respective thermistors if they are shorted or opened internally. Check the resistance value at the connector pins in the bottom of the fuser unit. (Refer to section 6.1 Resistance check (fuser unit).) Replace the fuser unit. Installed condition of fuser unit. Check if the fuser nit is pressed in until the connector in the bottom of the fuser unit is surely connected. Re-set the fuser unit.
Error occurs approx. 1 minute after the power is turned on.
(11-2-1) Temperature increase of fuser unit Thermostat, halogen lamp Heater of the fuser unit is controlled of its temperature. Check if the fuser unit gets hot or not by touching it with hands. If the fuser unit temperature does not increase and remains cold, check that the resistance between pin-1 and pin-2, and that in between pin-3 and pin-4 of the two connectors is in the range of several ohms to several ten ohms respectively. (Refer to section 6.1 Resistance value (fuser unit).) Replace the fuser unit. (11-2-2) Temperature increase of fuser unit Installation position of the upper thermistor Check if the upper thermistor is installed in the far position from the specified position or not causing detection of the lower temperature than the actual temperature of fuser unit. Remove the heater cover, and check warpage of sensor by visual inspection. Replace the fuser unit. Installation position of the lower thermistor The lower thermister must be installed while contacting with the fuser unit. Check if the lower thermister is installed in the far position from the specified position or not causing detection of the lower temperature than the actual temperature of fuser unit. Replace the fuser unit. (11-2-3) AC power input to the halogen lamp AC power voltage from the low voltage power supply Check if the AC voltage for heater is normally supplied or not. Power supply CN2 connector, between pin-1 and pin-2, and between pin-3 and pin-4. Replace the low voltage power supply. Heater ON signal that is output from CU/PU to the low voltage power supply Check that the heater ON signal goes active at the warming up timing, or not. "L" active while ON. CU/PU board POWER connector pin-2 and pin-4. Replace the CU/PU board.

← Xem tất cả mã lỗi OKI MC573dn

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie