Code: 922.07
Description: Fuser warm-up failure Fuser type = 1 The fuser hot roll does not reach operating temperature after increasing interpage gap.
Remedy: 1. Turn the machine off/on and ensure the fuser unit assembly is properly installed. 2. Ensure the proper voltage fuser is installed in the machine. 3. Check all connections on the fuser and LVPS card assembly. 4. Replace the fuser unit assembly if problem remains. Go to “Fuser unit assembly removal (X651, X652, X654, X656, and X658)”. 5. Replace the LVPS card assembly if problem remains. Go to “LVPS card assembly removal (X654, X656, and X658)”.