Mã lỗi 2-3 — OKI MPS730b

Code: 2-3

Description: Main Motor Abnormality - Rotation of MAIN MOTOR does not reach the specified speed.
Remedy: FIP1.5 Possible causative parts: MAIN MOTOR GEAR ASSY HOUSING GEAR ASSY PLATE LVPS HVPS/MCU 1 Checking MAIN MOTOR installation Are MAIN MOTOR, GEAR ASSY HOUSING and GEAR ASSY PLATE installed correctly? With tool Go to step 2. Without tool Go to step 3. Reinstall obstructive parts. 2 Checking MAIN MOTOR for operation Does the MAIN MOTOR rotate, and each gear rotate normally? Checks by Chapter 2 Diagnostic [Main Motor Test]. Remove COVER LEFT to check. Replace HVPS/MCU. Go to step 3. 3 Checking GEAR ASSY HOUSING and GEAR ASSY PLATE for operation Does each gear rotate normally? Rotate and check each gear of GEAR ASSY HOUSING and GEAR ASSY PLATE. Go to FIP2.2 MAIN MOTOR. Replace the obstructive parts.