Code: 672
Description: Controller-to-operation panel communication error at startup
After the machine is powered on, the communication between the controller and the operation panel is not established, or communication with controller is interrupted after a normal startup. After startup reset of the operation panel, the attention code or the attention acknowledge code is not sent from the controller within 15 seconds. After the controller issues a command to check the communication line with the controller at 30-second intervals, the controller fails to respond twice.
After the machine is powered on, the communication between the controller and the operation panel is not established, or communication with controller is interrupted after a normal startup. After startup reset of the operation panel, the attention code or the attention acknowledge code is not sent from the controller within 15 seconds. After the controller issues a command to check the communication line with the controller at 30-second intervals, the controller fails to respond twice.
Causes: Controller stalled. Controller board installed incorrectly. Controller board defective. Operation panel connector loose or defective. The controller is not completely shutdown when you turn the main switch off.
Remedy: 1. Check the setting of SP5875-001. If the setting is set to "1 (OFF)", change it to "0 (OFF)". 2. Check the condition of the controller board. 3. Check the condition of the operation panel. 4. Replace the controller board. 5. Replace the operation panel. 6. Turn the main switch off, wait for one second or more, and turn the main switch on.