Code: 321
Description: No laser writing signal (F-GATE) error
The poling module does not detect the laser writing signal (F-GATE) asserting after the laser crosses 5 mm from the start point on the drum surface.
The poling module does not detect the laser writing signal (F-GATE) asserting after the laser crosses 5 mm from the start point on the drum surface.
Causes: • Defective BICU
• Loose connection on the fax controller or the printer controller
• Defective fax controller or printer controller
• Loose connection on the fax controller or the printer controller
• Defective fax controller or printer controller