Code: 142
Description: White level detection error
The white level cannot be adjusted to the second target level within the target during auto gain control.
The white level cannot be adjusted to the second target level within the target during auto gain control.
Causes: • Dirty exposure lamp or optics section • SBU board defective • SIOB defective • IPU board defective • BCU board defective • Harnesses are disconnected. • Exposure lamp defective • Lamp stabilizer defective • Scanner motor defective