Code: 552-03
Description: Heating roller warm-up error (sensor 2)
The heating roller temperature does not reach 80ўXC within the prescribed time. The center temperature of the heating roller does not reach the target reload permit temperature within the prescribed time. The center temperature of the heating roller does not reach the target reload permit pressure within the prescribed time.
The heating roller temperature does not reach 80ўXC within the prescribed time. The center temperature of the heating roller does not reach the target reload permit temperature within the prescribed time. The center temperature of the heating roller does not reach the target reload permit pressure within the prescribed time.
Causes: Dirty thermopile lenses. Defective heating roller thermistor. Input voltage out of the warranty (out of specification).
Remedy: 1. Check and clean the thermopile lenses. 2. Replace the thermopile 3. Replace the thermistor.