Mã lỗi 141 — Ricoh D118 MPC305SP GR-C1
Code:
141
Description: Black level detection error
The black level cannot be adjusted within the target value during the zero clamp.
Causes: Harness disconnected. Defective SBU
Remedy: 1. Check the cable connection 2. Replace the SBU.