Code: 547-03
Description: Zero cross error: low frequencies error
The zero cross signal is detected three times even though the heater relay is off when turning on the main power. The zero cross signal is not detected for 2 seconds even though the heater relay is on after turning on the main power or closing the front door. The detection error occurs twice or more in the 11 zero cross signal detections. This error is defined when the detected number of zero cross signals is less than 45.
The zero cross signal is detected three times even though the heater relay is off when turning on the main power. The zero cross signal is not detected for 2 seconds even though the heater relay is on after turning on the main power or closing the front door. The detection error occurs twice or more in the 11 zero cross signal detections. This error is defined when the detected number of zero cross signals is less than 45.
Causes: Unstable frequencies from utility power line. Defective fusing lamp relay circuit. Unstable power supply.
Remedy: 1. Turn off and on the main power switch. 2. Check the utility power line. 3. Check the connection of the PSU to controller board and replace the harness or controller board if necessary.