Code: 672
Description: Controller start up error
After the machine is powered on, the communication between the controller and the operation panel is not established, or communication with the controller is interrupted after a normal startup. After startup reset of the operation panel, the attention code (FDH) or the attention acknowledge code (FEH) is not sent from the controller within 30 seconds. After the controller issues a command to check the communication line 687with the controller at 30-second intervals, the controller fails to respond twice.
After the machine is powered on, the communication between the controller and the operation panel is not established, or communication with the controller is interrupted after a normal startup. After startup reset of the operation panel, the attention code (FDH) or the attention acknowledge code (FEH) is not sent from the controller within 30 seconds. After the controller issues a command to check the communication line 687with the controller at 30-second intervals, the controller fails to respond twice.
Causes: Controller stalled. Controller board installed incorrectly. Controller board defective. Operation panel connector loose or defective. The controller is not completely shut down when the main switch is turned off.
Remedy: 1. Check the setting of SP5-875-001. If the setting is set to "1 (OFF)", change it to "0 (ON)".