Code: 793-04, 794-04
Description: Exit guide plate motor error 1-bin tray (D586)
The machine does not detect a correct signal from the exit guide plate HP sensor while the exit guide plate motor is operating. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.
The machine does not detect a correct signal from the exit guide plate HP sensor while the exit guide plate motor is operating. The 1st detection failure issues a jam error, and the 2nd failure issues this SC code.
Causes: • Defective exit guide plate motor • Loosen connection • Motor overload • Defective exit guide plate HP sensor
Remedy: 1. Replace the exit guide plate HP sensor. 2. Replace the exit guide plate motor.