Code: 101
Description: Exposure lamp error
The standard white level could not be set properly when scanning the white plate during automatic white level adjustment.
The standard white level could not be set properly when scanning the white plate during automatic white level adjustment.
Causes: • White plate dirty • Spurious electrical noise on power supply line • Exposure lamp connection loose, broken, defective • Exposure lamp defective • High voltage power supply (power pack) harness loose, broken, defective • SBU defective • BCU defective • SIO defective
Remedy: 1. Check and clean the scanner mirror(s) and scanner lens. 2. Check and clean the shading plate. 3. Replace the exposure lamp. 4. Replace the scanner mirror(s) or scanner lens. 5. Replace the SBU board. 6. Replace the BCU board. 7. Replace the SIO board.