Code: 672
Description: Controller-to-operation panel communication error at startup
After powering on the machine, communication between the controller and operation panel does not begin, or the communication is interrupted after a normal startup.
After powering on the machine, communication between the controller and operation panel does not begin, or the communication is interrupted after a normal startup.
Causes: • Controller stalled • Controller board installed incorrectly
• Defective controller board
• Operation panel connector loose or defective
• Poor connection of DIMM and optional boards on the controller board 1. Check the setting of SP5875-001. If the setting is set to "1 (OFF)", change it to "0 (ON)".
• Defective controller board
• Operation panel connector loose or defective
• Poor connection of DIMM and optional boards on the controller board 1. Check the setting of SP5875-001. If the setting is set to "1 (OFF)", change it to "0 (ON)".