Mã lỗi SC626-01 ... SC626-03 — Ricoh D135 MPC6502SP CH-C1

Code: SC626-01 ... SC626-03

Description: SC626-01 D DUB communication error at power-on SC626-02 D DUB communication error during normal operation SC626-03 D DUB BREAK detection during normal operation. ASAP communication protocol error • A BREAK signal was detected at power-on. • Non-response (100 ms) was detected 3 times consecutively during normal operation. • NAK was received 3 times before ACK was received during normal operation. • A BREAK signal was detected during normal operation.
Causes: • DUB defective • PFB defective • Harness between DUB and PFB broken • Connecter between DUB and PFB disconnected • Unintended electrical noise
Remedy: • Replace the DUB. • Replace the PFB. • Replace the harness between DUB and PFB. • Replace the connector between DUB and PFB.