Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC440-03 — Ricoh D136 MPC8002SP CH-C1

Code: SC440-03

Description: Image Transfer Power Pack Voltage Leak (M). An interrupt checks the status of the power pack every 10 ms. This SC is issued if a problem exists with 50 consecutive samplings (500 ms). Details: SC issued when the image transfer power pack output current is leaking. The IOB checks for SC signals as described above.
Causes: • Image transfer power pack output current is leaking.
Remedy: Remove the high voltage cable from the output terminal of the image transfer power pack and check the following items. • PWM signal check If signal is fixed during image transfer, replace the cable or the IOB. • Image transfer power pack output check If output is fixed during image transfer, replace the power pack. If output is normal during image transfer, replace the high voltage cable, ITB or the transfer roller.

← Xem tất cả mã lỗi Ricoh D136 MPC8002SP CH-C1