Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC442-00 — Ricoh D136 MPC8002SP CH-C1

Code: SC442-00

Description: ITB Lift Error Even though the ITB lift motor rotates, the ITB lift sensor failed to detect the specified sensor feeler status within specified time. Details: • During home-positioning (operation for fixing the separated status) (separation movement) The sensor failed to detect the transition from “feeler present” to “feeler absent” (separation movement) within 2000 msec from the start of ITB lift motor rotation. • During normal contact/separation movement (printing/process control/MUSIC/forced toner consumption) Contact movement: The sensor failed to detect the transition from “feeler absent” to “feeler present” (contact) within 2000 msec from the start of ITB lift motor rotation. Separation movement: The sensor failed to detect the transition from “feeler present” to “feeler absent” (separation) within 2000 msec from the start of ITB lift motor rotation. • During contact/separation movement under special conditions (paper jam, paper end etc.) Separation movement: The sensor failed to detect the transition from “feeler present” to “feeler absent” (separation) within 2000 msec from the start of ITB lift motor rotation. Detection timing: During contact/separation movement Detection interval: 2msec or more
Causes: • Sensor smudged • Motor/sensor defective • Harness broken or problem with connection (such as a disconnected connector)
Remedy: • If smudged: cleaning • If defective or broken: replacement • Problem with connection: reconnection

← Xem tất cả mã lỗi Ricoh D136 MPC8002SP CH-C1

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie