Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC465 — Ricoh D136 MPC8002SP CH-C1

Code: SC465

Description: SC465-02 D PTR motor (K) Lock: Encoder 2 error SC465-03 D PTR motor (K) Lock: Encoder 1/2 error SC465-04 D PTR motor (K) Lock: Hole error SC465-05 D PTR motor (K) Lock: Overload error. Error detected by the TDCU. If a command sent from the TDCU indicates an error, the engine issues an SC. ASAP command: Motor lock detection setting value (engine to TDCU): 0x5B See table below for ASAP commands notifying SC detection. Details: TDCU Motor lock signal criteria: • Drum motor High if the motor speed is not within the range of target value ± 6.25%. Low if the motor speed is within the range of target value ± 6.25%. • ITB drive motor, PTR Motor High if the motor speed is not within the range of target value ± 6.25%. Low if the motor speed is within the range of target value ± 6.25%. Target value: If the default motor speed was adjusted using the SP, the adjusted value is used as the target value. Specification: When the motor is on, each lock signal is checked every 100 milliseconds. If the High status is detected 20 times consecutively, the machine determines that the motor is not running correctly. The machine issues an SC and stops the motor.
Causes: • Motor defective, connector disconnected, harness broken, IOB defective, unit torque increased. • PTR sensor smudged or defective • PTR sensor connector not set correctly, harness broken
Remedy: • Replace the motor / reconnect the connector / replace the harness / replace the IOB / replace the unit / replace the driven unit. • Clean the sensor / replace the sensor. • Reconnect the sensor connector. • Check the sensor harness.

← Xem tất cả mã lỗi Ricoh D136 MPC8002SP CH-C1

Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie