Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi SC505-03 — Ricoh D136 MPC8002SP CH-C1

Code: SC505-03

Description: LCT Tray Error (Lowering Timeout): D709 • During Tray initialization, the tray bottom plate was lowered for position check but the upper limit sensor was still on or none of lower limit sensor and paper sensors 1 to 4 became on after a specified time (30 seconds). • When paper has run out or when the lowering switch was pressed, the tray bottom plate was lowered but neither the lift sensor nor the lower limit sensor became on after a specified time (30 seconds).
Causes: • Lift motor defective/connecter disconnected • Upper limit sensor defective/connecter disconnected • Lift sensor defective/connecter disconnected • Lower limit sensor defective/connecter disconnected • Either of paper sensors 1 to 4 defective/connecter disconnected • Related harness broken • PCB defective
Remedy: • Replace or reconnect the lift motor. • Replace or reconnect the upper limit sensor. • Replace or reconnect the lift sensor. • Replace or reconnect the lower limit sensor. • Replace or reconnect the paper sensors 1 to 4. • Replace the corresponding harness. • Replace the PCB.