Code: SC555-00
Description: Heater 2: Heater Continuously On (Sensor 4: Thermopile: Pressure Roller Center) Target temperature was not reached (t7) seconds after reload. Time elapsed after reload (excluding paper transport time) (t8) D135 (Japan): t7 = 90, t8 = 90 D136 (Japan)/D135 (NA): t7 = 90, t8 = 90 D136 (NA)/D135 (EU)/D136(EU): t7 = 90, t8 = 90 D137 (Japan): t7 = 90, t8 = 90 D138 (Japan)/D137 (NA)/D138 (NA)/D137 (EU)/D138 (EU): t7 = 90, t8 = 90 Monitored at: All times, though SC is not issued when temperature is not controlled (when in off mode/sleep mode, when a door, excluding the toner supply door, is open, or when the heater relay is off).
Causes: • Thermopile detection error • Heater disconnection • Overheating prevention device worked.
Remedy: • Replace the thermopile. • Replace the heater. • Replace the unit.