Mã lỗi SC665-01 — Ricoh D136 MPC8002SP CH-C1

Code: SC665-01

Description: FFC set detection (Error between IPU and BCU) The HORUS port on the BCU is used for FFC connection detection to detect FFC (harness) disconnection and loose connection between BCU and IPU. By checking the "H" or "L" status of this port, the connection status can be checked. • Normal condition (Connector connected): "H" at the HORUS port on the BCU. • Abnormal condition (Connector not connected): "L" at the HORUS port on the BCU. Details: • When a connector is disconnected, the voltage level becomes "L" level (0V level) because there is a pull-down resistor in the BCU.
Causes: • FFC harness between BCU and IPU broken • FFC harness between BCU and IPU not connected fully • BCU damaged • IPU damaged
Remedy: • Replace the FFC harness between BCU and IPU. • Reconnect the FFC harness between BCU and IPU. • Replace the BCU board. • Replace the IPU.