Code: SC665-03

Description: FFC set detection (Error between IOB and PFB) The HORUS port on the BCU is used for FFC connection detection to detect FFC (harness) disconnection and loose connection between IOB and PFB. By checking the voltage level of the AD terminal, the connection status can be checked. Details: • When the harness between IOB and PFB becomes disconnected, the number of parallelly connected resistors changes and therefore the voltage input to the AD terminal changes.
Causes: • FFC harness between IOB and PFB broken • FFC harness between IOB and PFB not connected fully • BCU damaged • IOB damaged • PFB damaged
Remedy: • Replace the FFC harness between IOB and PFB. • Reconnect the FFC harness between IOB and PFB. • Replace the BCU board. • Replace the IOB. • Replace the PFB.