Code: SC702-05
Description: Protection device break error 5 (1-pass ADF) The non-interlock power supply system protection device broke the circuit with the 24V power supply on. Details: A motor defect or a short circuit occurred in either the feed motor, pull-out motor, intermediate motor, scanning motor, or exit motor and the noninterlock power system protection device broke the circuit.
Causes: • Motor defect in non-interlock power supply system. • Harness broken
Remedy: • Replace the feed motor, pull-out motor, intermediate motor, scanning motor, or exit motor. • Replace the harness of feed motor, pull-out motor, intermediate motor, scanning motor, or exit motor. • Replace the board.