Description: Main motor lock The machine detected motor lock (motor is not operating correctly)
Causes: • An obstruction has blocked operation of the main motor • Main motor harness loose or broken • Main motor or main motor driver board defective • Overload on the main motor
Remedy: 1. Replace the harness of the main motor. 2. Replace the motor. 3. Replace the main motor driver board. 4. Check for the blockages in the main motor mechanism.